10 350 μs Current Wave Meaning
Type 2 spd the type 2 spd is the main protection system for all low voltage electrical installations.
10 350 μs current wave meaning. For a 8 20 μs wave the values of t 1 t 2 and peak value of i m are deduced as α 0 0535 x 10 6 β 0 113 x 10 6 and i m vc 14 with lc 65. To characterize the current waves from a direct lightning stroke see fig. Protects equipment connected to it and is characterized by an 8 20 μs current wave. With this definition time to front t 1 t f 1 βtanh 1 β α and the time to tail t 2 is a complex function of both β and α.
2 types of current wave are considered by the iec standards. 100 ka 10 350 μs wave. Type 2 spd is characterized by an 8 20 µs. Type 1 spd is characterized by a 10 350 µs current wave.
They must therefore only be installed as a supplement to type 2 spd and in the vicinity of sensitive loads and are characterised by a combination of voltage waves 1 2 50 μs and current waves 8 20 μs. J9 10 350 µs current wave. Putting 10 350 under the microscope. Analysis of the phenomena allows definition of the types of lightning current and voltage waves.
Some insidious and all unnecessary. Discharge current i max surge current 8 20 µs current impulse only für spd type 2 combination wave u. The 10 350 waveform causes iec standards a number of undesirable problems. The hard fact to face is that standards that enforce the 10 350 waveform test and impose spark gap protectors on the world are not just innocent bystanders.
Recommended by ieee std c62 41 2 2002 are the 100 khz ring wave and the 1 2 50microsec to 8 20microsec combination wave the latter involving two waveforms one for voltage and the other for current. The iec ieee 10 350 us microsecond waveform is an approximation of the surge current waveform experienced for a primary lightning strike. Type 3 these spds have a low discharge capacity. In order to meet the impulse current i imp.
Impulse discharge current i imp lightning currents 10 350 µs current impulse only for spd type 1 nominal discharge current i n surge currents 8 20 µs current impulse only für spd type 2 max. If not please set me straight. Installed in each electrical switchboard it prevents the spread of overvoltages in the electrical installations and protects the loads. There is some validity in the proposal of 10 350 as a test wave sometimes cited as a solution in search of a problem for some marketing approaches but if wg 3 6 4 would instead of arguing about duplicating lightning versus show me a recording of 10 350 propose and accept the arbitrary 10 350 as a useful spd characterization test actually the scope of 3 6 9 we might succeed in.